| -- | -- | Hgw2372 | (D) DIN 7735 |
| -- | -- | EP GC 201 | EN 60893 / IEC 893 |
| -- | -- | 3953-EP 3 | GB) BS |
| -- | -- | G 10 | USA) NEMA L1 |
| -- | -- | 1 51-VT-EE 1 | F) NF C26 |
| -- | -- | S-EP GC 1 | CH) VSM |
| -- | -- | epoxy | Resin |
| -- | -- | glassfilam. | Reinforcement |
| -- | -- | fabric | |
| Density | DIN 53479 | 1,7-1,9 | g/cm3 |
| Flexural strength. unproces./ 23 C | DIN 53452 | 350 | MPa |
| Impact strength a a | DIN 53453 | 100 | kJ/m |
| Notched bar impact value a | DIN 53453 | 50 | kJ/m |
| Notched bar impact value a | DIN 53453 | - | kJ/m |
| Tensile strength s | DIN 53455 | 220 | MPa |
| Compressive strength o | DIN 53454 | 200 | MPa |
| Split load | DIN 53463 | 3000 | N |
| Modulus of elasticity -bending test | DIN 53457 | 18000 | MPa |
| Resistance between plugs | . | -- | |
| after 24 h storage in water 23°C | DIN 53482 | 5*10^-10 | Ohm |
| 1-minute test voltage | | -- | 1-minute test voltage |
| parallel to lemination | DIN 53481 | 40 | kV |
| 1-minute test voltage | - | -- | - |
| perpendicular to Lamintaion | DIN 53481 | 40 | kV |
| Dielectric loss factor tan d | -- | -- | Dielectric loss factor tan d |
| -50Hz 96h105°C | DIN 53483 | 0,05 | max. |
| -1 MHz 24 h storage in water | DIN 53483 | 0,04 | max. |
| Dielectric constant | DIN 53483 | 5 | >> |
| Tracking resistance index 6) | IEC 112 | 200 | CTI |
| Electrolytic corrosion | DIN 53489 | AN 1,4 | max. |
| Arc resistance | DIN 53484 | | class |
| Thermal conductivity | DIN 52612 | 0,3 | W/m*k |
| Linear expansion coefficient | VDE 0304/2 | 10-20 | 10 |
| Temperature Index | VDE 0304/2 | 130 | °C |
| Limit value determin. of the limit temp. | | -- | Limit value determin. of the limit temp. |
| based on fiexural str. óbB | - | 175 | MPa |
| Flammability | UL 94 | - | class |
| Oxygen index | ISO 4589 | - | Oxygen index |
| Insulating class | IEC Publ.85 | B | % |
| Glow rod test | DIN 53459 | 2a | class |
| Water absorbtion. 4mm thickness | DIN 53495 | 28 | mg |
| Colour | -- | green - brown | Colour |